Part No.39530852, IR air compressor regulating solenoid valve
Categories
Part No.39530852, IR air compressor regulating solenoid valve
Product description: Part No.39530852, IR air compressor regulating solenoid valve, 1/4 inch thread, screw air compressor electromagnetic switch
5-Minute Initial Response
Product description:
- When the solenoid is energized (load signal): the valve switches the pilot air to open the inlet valve, so the compressor loads and delivers compressed air at full output.
- When the solenoid is de-energized (unload signal): the inlet valve closes and the system vents, so the compressor unloads and runs at no-load with minimal power consumption and no air delivery.
| Item | Specification |
|---|---|
| Part number | 39530852 |
| Part type | Regulating solenoid valve (electromagnetic switch) |
| Valve type | 3-way load / unload control (per public listings) |
| Thread | 1/4″ |
| Application | Ingersoll Rand rotary screw air compressors |
| Compatible series | SSR (M15–M37), UP6, Nirvana (Variable Speed) (per public listings) |
| Voltage | [Confirm against original valve] |
Product Advantages
- OEM-reference matched — manufactured to match the Ingersoll Rand original part specification for a direct drop-in replacement.
- 3-way load / unload regulation — precisely switches the pilot air to control the inlet valve and keep the compressor running at the right capacity.
- 1/4″ thread — matched to the IR control configuration.
- Broad compatibility — fits IR rotary screw series including SSR (M15–M37), UP6 and Nirvana (Variable Speed) models (per public listings).
- Saves energy — correct loading / unloading lets the compressor run at no-load when there is no air demand, reducing power consumption and running costs.
- Stable system pressure — precise control response keeps the compressed air pressure within the set range.
- Quick to replace — compact electromagnetic switch that can be swapped out directly by service technicians familiar with the machine.
FAQ
Q1: What is this regulating solenoid valve used for?
A: It is the electromagnetic load / unload control switch on an Ingersoll Rand rotary screw air compressor. It switches the pilot air that operates the inlet valve, so the compressor can load (deliver compressed air at full output) or unload (run at no-load) according to the air demand. This keeps the system pressure stable and saves energy.
Q2: What is the valve type and thread size?
A: The 39530852 is a 3-way load / unload regulating solenoid valve (per public listings) with a 1/4″ thread. Please confirm the thread, port size and wiring against your original valve before ordering.
Q3: What is the voltage?
A: Ingersoll Rand solenoid valves are available in different voltage versions. Please confirm the voltage and coil type against your original valve and your compressor’s control circuit before ordering. If you need a specific voltage, tell us and we will confirm availability before shipping.
Q4: Which Ingersoll Rand compressors does it fit?
A: Per public listings, the 39530852 fits IR rotary screw compressors including the SSR series (M15–M37), UP6 series and Nirvana (Variable Speed) models. Before ordering, please confirm the part number on your original valve and your compressor model, or send us your machine details and we will help you confirm compatibility.
Q5: What are the symptoms of a faulty regulating solenoid valve?
A: Common signs include: the compressor fails to load (runs idle but delivers no air / cannot reach set pressure), fails to unload (keeps running loaded, pressure keeps rising), unstable or fluctuating system pressure, the solenoid coil getting hot or burnt out, the machine clicking but not responding, and high energy consumption. Any of these can indicate the valve is stuck, the coil is open-circuit, or the spool is jammed.
Q6: How do I check whether the solenoid valve is working?
A: A basic check: observe whether the valve clicks and whether the machine loads / unloads when the controller signals. Check the coil with a multimeter for continuity and measure the supply voltage at the connector. For the valve spool, remove the valve and check that the spool / plunger moves freely and is not stuck or clogged. If the coil is open-circuit or the spool is jammed, replace the valve.
Q7: When should I replace it?
A: Replace the regulating solenoid valve when the machine shows the symptoms above, when the coil is open-circuit or burnt, when the valve is stuck and cannot be cleaned, or during a major overhaul after long service hours. Replacing it restores normal regulation and prevents unreliable pressure and high running costs.
Q8: Is this an original Ingersoll Rand part?
A: This is a replacement part manufactured to match the Ingersoll Rand OEM specification; some public suppliers also list it as a genuine OEM part. If you specifically require an original part, please let us know before ordering.
Q9: Is installation difficult?
A: No — the solenoid valve is a compact electromagnetic switch that can be replaced directly by service technicians familiar with the machine. Before installation, depressurize the compressor and disconnect the power, note the original wiring and pilot-air connections, fit the new valve and reconnect, then verify the load / unload function after restart. If you need installation guidance, please contact us.
Get a Quote for Your Compressor Part
Looking for the right replacement part? Send us your part number, compressor model, or dimensions, and our team will help you confirm the correct product.