Part No.1089070213/1089070209
Product description:
- When the solenoid is energized: the valve switches the pilot air to load the compressor — the inlet valve opens so the compressor draws in air and delivers compressed air at full output.
- When the solenoid is de-energized: the valve switches the pilot air to unload the compressor — the inlet valve closes and the system vents, so the compressor runs at no-load with minimal power consumption and no air delivery.
| Item | Specification |
|---|---|
| Part numbers | 1089070213 / 1089070209 |
| Part type | Solenoid valve, new style |
| Voltage | 110V AC |
| Valve type | 3/2-way (per related part 1089070214) |
| Application | Atlas Copco screw air compressors |
Product Advantages
- Interchangeable part numbers in one listing — 1089070213 and 1089070209 cover the same 110V solenoid valve application, so you can match the number on your original valve.
- 110V AC — confirmed — matched to the Atlas Copco 110V control circuit (new-style configuration).
- OEM-reference matched — manufactured to match the Atlas Copco original part specification for a direct drop-in replacement on Atlas Copco screw air compressors.
- Reliable electromechanical switching — quality solenoid coil and valve spool deliver dependable load / unload switching through every operating cycle.
- New-style design — updated solenoid valve configuration matched to current Atlas Copco compressor control systems.
- Saves energy — correct loading / unloading lets the compressor run at no-load when there is no air demand, reducing power consumption and running costs.
- Stable system pressure — precise control response keeps the compressed air pressure within the set range.
- Quick to replace — compact solenoid valve that can be swapped out directly by service technicians familiar with the machine.
FAQ
A: It is an electromagnetic control solenoid valve on an Atlas Copco screw air compressor. It switches the pilot air that operates the inlet valve and the blowdown function, so the compressor can load (deliver compressed air at full output) or unload (run at no-load) according to the air demand. This keeps the system pressure stable and saves energy.
A: The listing covers two part numbers — 1089070213 and 1089070209 — which are interchangeable 110V solenoid valves for the same application. You can match whichever number is marked on your original valve. If you are not sure whether your machine uses one of these, send us your machine model and original part number and we will help you confirm.
A: Both valves are 110V AC. They are solenoid valves for screw air compressors; the related part 1089070214 in the same series is a 3/2-way valve, and these valves serve the same control function. Please confirm the coil, port size and wiring against your original valve before ordering.
A: “New style” indicates this is the updated solenoid valve configuration used on current Atlas Copco screw air compressor control systems, matched to the 110V new-style control circuit. If your machine uses this new-style valve, it is the correct replacement.
A: These 110V solenoid valves fit Atlas Copco rotary screw air compressors that use these part numbers in their control circuit. Before ordering, please confirm the part number on your original valve and your compressor model, or send us your machine details and we will help you confirm compatibility.
A: Common signs include: the compressor fails to load (runs idle but delivers no air / cannot reach set pressure), fails to unload (keeps running loaded, pressure keeps rising), unstable or fluctuating system pressure, the solenoid coil getting hot or burnt out, the machine clicking but not responding, and high energy consumption. Any of these can indicate the valve is stuck, the coil is open-circuit, or the spool is jammed.
A: A basic check: observe whether the valve clicks and whether the machine loads / unloads when the controller signals. Check the coil with a multimeter for continuity and measure the supply voltage (110V) at the connector. For the valve spool, remove the valve and check that the spool / plunger moves freely and is not stuck or clogged. If the coil is open-circuit or the spool is jammed, replace the valve.
A: Replace the solenoid valve when the machine shows the symptoms above, when the coil is open-circuit or burnt, when the valve is stuck and cannot be cleaned, or during a major overhaul after long service hours. Replacing it restores normal control and prevents unreliable pressure and high running costs.
A: This is a replacement part manufactured to match the Atlas Copco OEM specification; if you require an original part, please let us know. Installation is straightforward for service technicians familiar with the machine: depressurize the compressor and disconnect the power, note the original wiring, fit the new valve and reconnect the coil leads, then verify the load / unload function after restart. If you need installation guidance, please contact us.
Get a Quote for Your Compressor Part
Looking for the right replacement part? Send us your part number, compressor model, or dimensions, and our team will help you confirm the correct product.