39418926, 39146741, 42552950, SD-492789 Loading Solenoid Valve
Categories
39418926, 39146741, 42552950, SD-492789 Loading Solenoid Valve
Product description: 39418926, 39146741, 42552950, SD-492789 Loading Solenoid Valve for IR Air Compressor, in stock, compressor spare parts
5-Minute Initial Response
Product description:
- When the solenoid is energized (load signal): the pilot air moves to open the inlet valve, so the compressor draws in air and delivers compressed air to the system at full output.
- When the solenoid is de-energized (unload signal): the inlet valve closes and the blowdown valve vents the separator tank pressure, so the compressor runs at no-load with minimal power consumption and no air delivery.
| Item | Specification |
|---|---|
| Part numbers | 39418926 / 39146741 / 42552950 / SD-492789 |
| Part type | Loading (load/unload) solenoid valve |
| Voltage | 110V AC (per parts 39418926 / 39146741) |
| Application | Ingersoll Rand oil-injected screw air compressors |
| Reference models | IR ML45-75, VHP650/750 (per public listings) |
Product Advantages
- Interchangeable part numbers in one listing — 39418926, 39146741, 42552950 and SD-492789 cover the same loading solenoid valve application, making it easy to match the number on your original valve.
- OEM-reference matched — manufactured to match the Ingersoll Rand original part specification for a direct drop-in replacement on IR screw air compressors.
- Reliable electromechanical switching — quality solenoid coil and valve spool deliver dependable load / unload switching through every operating cycle.
- 110V AC standard voltage — matched to the IR control voltage used on many IR screw compressors (per parts 39418926 / 39146741).
- Saves energy — correct loading / unloading lets the compressor run at no-load when there is no air demand, reducing power consumption and running costs.
- Stable system pressure — precise load / unload response keeps the compressed air pressure within the set range.
- In stock, ready to ship — stocked part for fast delivery and minimal machine downtime.
- Quick to replace — compact solenoid valve that can be swapped out directly by service technicians familiar with the machine.
FAQ
A: It is the electromagnetic pilot valve of an air compressor’s load / unload control system. It switches the pilot air that operates the inlet valve and blowdown valve, so the compressor can load (deliver compressed air at full output) or unload (run at no-load with minimal power) according to the air demand. This keeps the system pressure stable and saves energy.
A: The listing covers four part numbers — 39418926, 39146741, 42552950 and SD-492789 — which are interchangeable part numbers for the same loading solenoid valve application. You can match whichever number is marked on your original valve. If you are not sure whether your machine uses one of these, send us your machine model and original part number and we will help you confirm.
A: Parts 39418926 and 39146741 are 110V AC solenoid valves. Please confirm the voltage of your original valve and your compressor’s control circuit before ordering, as 42552950 / SD-492789 may differ. If you need a different voltage, please contact us and we will check availability.
A: These loading solenoid valves fit Ingersoll Rand oil-injected rotary screw air compressors that use these part numbers. Public listings reference IR ML45-75 and VHP650/750 models. Before ordering, please confirm the part number and your compressor model, or send us your machine details and we will help you confirm compatibility.
A: Common signs include: the compressor fails to load (runs idle but delivers no air / cannot reach set pressure), fails to unload (keeps running loaded, pressure keeps rising, frequent loading), unstable or fluctuating system pressure, the solenoid coil getting hot or burnt out, the machine clicking but not responding, and high energy consumption. Any of these can indicate the solenoid valve is stuck, the coil is open-circuit, or the spool is jammed.
A: A basic check: with the compressor running, observe whether the valve clicks and whether the machine loads / unloads when the controller signals. You can also check the coil with a multimeter for continuity and measure the supply voltage at the connector. For the valve spool, remove the valve and check that the spool / plunger moves freely and is not stuck or clogged. If the coil is open-circuit or the spool is jammed, replace the valve.
A: Replace the loading solenoid valve when the machine shows the symptoms above, when the coil is open-circuit or burnt, when the valve is stuck and cannot be cleaned, or during a major overhaul after long service hours. Replacing it restores normal load / unload control and prevents unreliable pressure and high running costs.
A: This is a replacement part manufactured to match the Ingersoll Rand OEM specification. If you specifically require an original Ingersoll Rand part, please let us know before ordering.
A: No — the loading solenoid valve is a compact electromechanical part that can be replaced directly by service technicians familiar with the machine. Before installation, depressurize the compressor and disconnect the power, note the original wiring, fit the new valve and reconnect the coil leads, then verify the load / unload function after restart. If you need installation guidance, please contact us.