36920825 Pressure Sensor
Product description:
- The sensor / transducer converts the air pressure it senses into an electrical signal (per IR service manuals, typically 0.5–4.5 VDC) that the controller can read.
- The controller uses the pressure reading to run the compressor: load when the pressure is low, unload when the set pressure is reached, and keep the system pressure within the working range.
- A faulty sensor gives an incorrect or failed reading, so the controller cannot regulate the pressure correctly.
| Item | Specification |
|---|---|
| Part number | 36920825 |
| Part type | Pressure sensor / pressure transducer (pressure transmitter) |
| Pressure range | 0–100 psi (per IR parts manuals / listing) |
| Output signal | 0.5–4.5 VDC (IR service manual, per listing) |
| Application | Ingersoll Rand air compressors (portable models referenced) |
| Sensing type | Resonant, semiconductor type (per listing) |
| Also grouped with | 39929435, 54496773 (per listings) |
| Electrical spec | [Confirm against original sensor] |
Product Advantages
- Known measurement range — referenced at 0–100 psi in IR parts manuals and listings.
- Referenced in IR official parts lists — appears in IR / Doosan portable compressor parts manuals as the 100 psi pressure transducer.
- OEM-reference matched — replacement sensor manufactured to match the Ingersoll Rand pressure transducer specification.
- Referenced for IR compressors — fits the corresponding IR portable compressor sensor position.
- Accurate pressure monitoring — correct reading lets the controller regulate loading / unloading and working pressure properly.
- Stable system pressure — avoids the unstable pressure caused by a faulty sensor.
- Protects efficiency — correct control avoids unnecessary loading / unloading and wasted energy.
- Prevents false trips / alarms — a working sensor stops the incorrect readings that cause alarms and shutdowns.
FAQ
A: It is the pressure sensor / pressure transducer of an Ingersoll Rand air compressor. It measures the compressed-air pressure and sends a signal to the controller, which uses the reading to regulate loading, unloading and the working pressure.
A: Per IR parts manuals and listings this sensor is referenced at 0–100 psi. Please confirm the range matches your machine’s requirement before ordering.
A: This is the pressure sensor for Ingersoll Rand air compressors; it is referenced in IR / Doosan parts manuals for the corresponding portable compressor models as the 100 psi transducer. Please confirm the exact machine model and the sensor spec against your original part before ordering; if you are not sure, send us your machine details and we will help you confirm.
A: Per IR service manuals this type of transducer outputs 0.5–4.5 VDC, corresponding to 0 psi up to the maximum measured psi. Please confirm the output matches your controller’s input before ordering.
A: Per listings, 36920825 is grouped with 39929435 and 54496773 in IR pressure-sensor cross-references. Please confirm the correct number for your machine before ordering.
A: The sensor converts the air pressure it senses into an electrical signal that the controller can read. The controller uses the reading to load the compressor when pressure is low and unload when the set pressure is reached, keeping the system within the working range.
A: Common signs include: unstable or incorrect system pressure, the compressor loading / unloading at the wrong times, pressure readings that are inaccurate, erratic or failed, and repeated pressure alarms or trips. Any of these can indicate the sensor needs replacing.
A: Compare the sensor reading against a known-good gauge / the actual system pressure. If the reading is inaccurate, erratic or missing, the sensor may be faulty. Check the wiring / connector first, then confirm the sensor against the original specification before replacing.
A: This is a replacement sensor manufactured to match the Ingersoll Rand OEM specification; if you require an original Ingersoll Rand part, please let us know. Replacing the sensor is normally a straightforward swap carried out by service technicians: isolate and depressurize the line, disconnect the wiring, replace the sensor, reconnect and verify the reading after restart. If you need service guidance, please contact us.
Get a Quote for Your Compressor Part
Looking for the right replacement part? Send us your part number, compressor model, or dimensions, and our team will help you confirm the correct product.