The 25K-Y — also referenced as MPV-25K-Y or MPV25KY — is a minimum pressure valve (MPV), also called a pressure maintenance valve or pressure holding valve, for oil-injected rotary screw air compressors. In the model name, “25” stands for the nominal diameter DN25 (1″ / G1), “K” indicates the K-type threaded connection, and “-Y” identifies this specific variant of the MPV-25K series. It is a universal replacement part commonly specified on Kaishan (开山) and other brand oil-injected screw compressors that use an MPV-25K valve, typically on machines in the approx. 22 kW /up to 4.3 m³/min class.
Typical specifications (MPV-25 series)
表格
Item Specification
Nominal diameter DN25 (1″ / G1)
Connection type K-type threaded (G1)
Opening pressure 4 – 5 bar (0.4 – 0.5 MPa)
Max. working pressure 16 bar
Recommended max. FAD approx. 4.3 m³/min
Please confirm the exact opening pressure and connection against your original valve or machine service manual.
What it does — the pressure holding valve of the compressor
The 25K-Y is a spring-loaded, pressure-controlled valve installed at the air outlet of the oil-gas separator tank. It consists of a valve body, piston / valve core, spring, sealing rings and an adjusting screw, and it automatically opens and closes according to system pressure. It performs four essential jobs:
  1. Holds minimum pressure in the separator tank — the valve stays closed until the tank pressure reaches the calibrated opening value (4–5 bar). By keeping pressure inside the tank, it ensures the oil-laden compressed air is properly separated in the separator element, which directly reduces oil carryover and oil loss.
  2. Builds oil circulation pressure — the pressure held in the tank pushes lubricating oil through the oil circuit to the screw element and bearings, guaranteeing lubrication and cooling during start-up and low-load running. Without this pressure, the machine can overheat very quickly.
  3. Protects the oil separator element — by controlling the flow rate and avoiding sudden large pressure differences, the valve shields the precision separator element from pressure shock and extends its service life.
  4. Works as a check valve — when the compressor unloads or stops, the valve closes automatically and stops compressed air in the downstream piping from flowing back into the compressor.
Why replacement matters
With long running hours, the spring weakens, the piston wears, and the seals harden or leak. A failing minimum pressure valve can trigger a chain of problems: oil in the compressed air (oil carryover), higher oil consumption, poor lubrication leading to overheating, inability to reach rated pressure, unstable outlet pressure, and air backflow on shutdown. Replacing the 25K-Y restores stable separator pressure, protects the separator element and airend, and keeps the compressor running reliably.

Product Advantages

  • DN25 (1″ / G1) K-type threaded connection — compact screw-in design that fits directly into the separator outlet of compressors using an MPV-25K valve; easy to install even in tight spaces.
  • Calibrated 4–5 bar opening pressure — factory-set to the standard MPV-25 series opening range, holding the separator tank at the pressure needed for proper oil separation and lubrication.
  • 16 bar max. working pressure — built to handle the full operating pressure range of standard oil-injected screw compressors.
  • Sized for up to approx. 4.3 m³/min compressors — matched to small-to-medium screw compressors (typically around 22 kW class) that require a DN25 minimum pressure valve.
  • Reduces oil carryover and oil consumption — enough holding pressure lets the separator element remove oil droplets effectively, so less oil escapes into the downstream air line and oil consumption stays within normal range.
  • Guarantees lubrication and prevents overheating — the retained tank pressure drives oil to the screw element and bearings, protecting the machine from overheating and premature wear, especially at start-up and low load.
  • Protects the expensive separator element — controlled opening avoids sudden pressure shocks and large pressure differences across the separator element, lengthening the service life of this precision filter.
  • Prevents air backflow — acts as a dependable check valve when the compressor unloads or stops, preventing compressed air in the piping from blowing back into the machine.
  • Durable metal construction — quality metal valve body, piston and spring, paired with reliable sealing rings, built to withstand continuous high-pressure compressor working conditions.
  • Correct -Y variant — manufactured to match the 25K-Y / MPV-25K-Y specification; if your original valve is marked 25K-Y, this is the direct replacement.

FAQ

Q1: What is a 25K-Y minimum pressure valve used for?

A: It is a pressure-control and check valve fitted at the outlet of the oil-gas separator tank on an oil-injected screw air compressor. It holds a minimum pressure inside the separator tank (so oil is properly separated and lubricating oil circulates correctly), protects the separator element from pressure shock, and prevents compressed air from flowing back when the machine unloads or stops.

Q2: What does “25K-Y” mean? Will it fit my compressor?

A: “25” = nominal diameter DN25 (1″ / G1); “K” = K-type threaded connection; “-Y” = the specific variant of this model. This valve fits oil-injected rotary screw air compressors that use a 25K-Y / MPV-25K minimum pressure valve (commonly found on Kaishan and similar brand machines, typically around 22 kW). Before ordering, please confirm the model marking on your original valve and the connection size, or send us your compressor model and we will help you confirm.

Q3: What are the technical specifications?

A: For the MPV-25 series: nominal diameter DN25 (1″ / G1), opening pressure 4–5 bar (0.4–0.5 MPa), maximum working pressure 16 bar, threaded G1 connection, recommended maximum flow approx. 4.3 m³/min. These are typical values for the MPV-25 series — please confirm the exact opening pressure and thread type against your original valve or service manual.

Q4: What is the difference between 25K-Y and other 25-size variants (25A, 25F, 25K, -Y / -N)?

A: All 25-size models (25A, 25B, 25F, 25K, etc.) share the same DN25 nominal diameter and similar pressure ratings, but differ in connection type — for example, A/B/K are threaded variants, while F is a flanged variant. The “-Y” and “-N” suffixes identify different production variants of the same model. You should always match the full model marking (e.g. 25K-Y) on your original valve. If you are not sure, send us a photo of the old valve.

Q5: Where is the minimum pressure valve installed?

A: It is installed at the compressed-air outlet of the oil-gas separator tank (usually on the upper part of the separator barrel), between the separator element outlet and the aftercooler / downstream piping.

Q6: What are the symptoms of a faulty minimum pressure valve?

A: Common signs include: excessive oil in the compressed air (oil carryover), higher-than-normal oil consumption, the compressor overheating due to poor oil circulation, inability to reach the rated discharge pressure, unstable or fluctuating outlet pressure, and air blowing back from the machine when it stops. Any of these can indicate the valve is stuck, the spring has weakened, or the seals have failed.

Q7: How do I check whether my minimum pressure valve is working?

A: A basic in-machine check: start the compressor and watch the separator tank pressure. The tank pressure should build up to the calibrated opening value (around 4–5 bar) before air starts flowing to the downstream line. If air flows out immediately at very low pressure, the valve is likely stuck open; if the tank pressure keeps rising but no air reaches the outlet, the valve may be stuck closed. For an accurate result, remove the valve, inspect the piston, spring and seals, and test the opening pressure on a test bench.

Q8: When should I replace it, and what is included?

A: Replace it when the machine shows the symptoms above, when the valve fails the opening-pressure test, when air or oil leaks appear around the valve body, or during a major overhaul after long service hours. The 25K-Y is supplied as a complete valve assembly (valve body, piston / core, spring and seals). If you only need a repair kit (seals / spring) instead of the full valve, please contact us separately.

Q9: Is installation difficult?

A: No — the 25K-Y is a compact, threaded maintenance part that can be replaced directly by service technicians familiar with the machine. Before installation, release all pressure from the system, clean the valve seat and threads, fit the new valve with the correct seals (use thread sealant as appropriate), and after installation verify the opening pressure and check for air leaks. If in doubt, contact us for installation guidance.

Get a Quote for Your Compressor Part

Looking for the right replacement part? Send us your part number, compressor model, or dimensions, and our team will help you confirm the correct product.

Scroll to Top
air compressor parts
                     Contact us 

        Email:sales@globalcompparts.com

Whatsapp:86 15797923361

Need Air Compressor Parts?