41*62 Thermostatic Valve Core
Product description:
- The valve core is fitted inside the compressor’s thermostat valve body, which controls the flow of oil between the cooler and the bypass circuit.
- When the oil is cold (start-up): the core stays contracted and the valve routes the oil through the bypass, so the oil heats up quickly to operating temperature. This prevents condensation forming in the airend, which could damage the screw and bearings.
- When the oil warms up: the thermal element inside the core expands, moving the valve to route the oil through the oil cooler, where the heat is removed, keeping the oil temperature stable.
- This valve core is typically rated to open / respond at around 60–70°C (confirm the opening temperature against your original core).
- It is the replaceable core inside the thermostat valve of a screw air compressor — the part that does the actual temperature sensing and valve actuation.
- Sizes 41*62, 45*62 and 58*73 are common family variants (diameter × length); choose the size that matches your valve body.
- It is commonly used on screw air compressors that fit this valve-core size (per listings, incl. machines such as Hongwuhuan / Jufeng / Linggefeng series).
| Item | Specification |
|---|---|
| Valve core size | 41 mm × 62 mm (diameter × length) |
| Part type | Thermostatic valve core (temperature control element) |
| Material | Brass (all-copper) |
| Opening temperature | ~60–70°C (confirm against original core) |
| Related sizes | 45×62, 58×73 (family variants) |
| Test method | Heat in hot water (e.g. 70°C) to check the element expands / moves |
Product Advantages
- Correct size 41*62 — 41 mm diameter × 62 mm length, matched for the corresponding thermostat valve body.
- Brass (all-copper) construction — durable thermal element, resistant to hot oil and repeated cycling.
- Restores oil-temperature control — a fresh core routes the oil correctly between the cooler and the bypass, keeping the temperature stable.
- Prevents overheating — correct cooling avoids high oil / head temperature and over-temperature trips.
- Protects the airend — proper warm-up on start-up prevents condensation damage to the screw and bearings.
- Cost-effective rebuild — replace the core inside the existing valve instead of replacing the whole valve assembly.
- Easy to test — the element can be checked by heating it in hot water to confirm it expands / moves.
FAQ
A: It is the temperature-sensing element inside the thermostat valve of a screw air compressor. It senses the oil temperature and moves the valve to route the oil between the cooler and the bypass, keeping the oil at the correct operating temperature.
A: 41*62 is the valve core size: 41 mm diameter × 62 mm length. Confirm this size against your valve body. Common family variants include 45*62 and 58*73 — choose the size that matches your valve.
A: The core contains a wax / liquid-filled thermal element. When the oil is cold, the element stays contracted and the valve routes the oil through the bypass so it heats up quickly (preventing condensation). As the oil warms up, the element expands and the valve routes the oil through the cooler to remove heat, keeping the temperature stable.
A: This valve core is typically rated to open / respond at around 60–70°C (per listings). Confirm the opening temperature against your original core and compressor before ordering; if you are not sure, send us your original valve-core details and we will help you match it.
A: This is a universal thermostatic valve core for the corresponding valve-body size on oil-injected screw air compressors. It is commonly used on machines that fit this core size (per listings, incl. machines such as Hongwuhuan / Jufeng / Linggefeng series). Please confirm the size and opening temperature against your original valve before ordering.
A: Heat the valve core in hot water (e.g. at the rated ~70°C opening temperature) and check that the thermal element expands / moves. If it does not respond, or if the compressor shows unstable / high oil temperature, the core likely needs replacing.
A: Common signs include: high oil / head temperature and over-temperature trips, slow warm-up on start-up, unstable oil temperature, and poor compressor performance. Any of these can indicate the valve core needs replacing.
A: Replace the valve core when it shows the symptoms above, during a major overhaul after long service hours, or when the element no longer responds correctly. Replacing the worn core restores correct oil-temperature control.
A: Replacing a valve core is normally done by service technicians familiar with the machine: drain the oil if needed, remove the thermostat valve, take out the old core, fit the new 41*62 core, refit and verify the oil temperature after restart. If you need service guidance, please contact us.
Get a Quote for Your Compressor Part
Looking for the right replacement part? Send us your part number, compressor model, or dimensions, and our team will help you confirm the correct product.