49154016/22359632 Interchangeable Pressure Sensor
Product description:
- The sensor / transducer converts the air pressure it senses into an electrical signal that the controller can read.
- The controller uses the pressure reading to run the compressor: load when the pressure is low, unload when the set pressure is reached, and keep the system pressure within the working range.
- A faulty sensor gives an incorrect or failed reading, so the controller cannot regulate the pressure correctly.
| Item | Specification |
|---|---|
| Part numbers | 49154016 / 22359632 (interchangeable, per listings) |
| Part type | Pressure sensor / pressure transducer |
| Application | Ingersoll Rand air compressors (screw type, per listing) |
| Also grouped with | 24571283, 23451859, 23800584 (per listings) |
| Measurement range / electrical spec | [Confirm against original sensor] |
Product Advantages
- Two interchangeable part numbers — 49154016 / 22359632 are cross-referenced as the same IR pressure sensor (per listings), so you can match whichever number your machine references.
- OEM-reference matched — replacement sensors manufactured to match the Ingersoll Rand pressure sensor specification.
- Referenced for IR screw compressors — 49154016 is referenced as the IR screw air compressor pressure sensor (per listing).
- Accurate pressure monitoring — correct reading lets the controller regulate loading / unloading and working pressure properly.
- Stable system pressure — avoids the unstable pressure caused by a faulty sensor.
- Protects efficiency — correct control avoids unnecessary loading / unloading and wasted energy.
- Prevents false trips / alarms — a working sensor stops the incorrect readings that cause alarms and shutdowns.
- Direct replacement — the sensor can be fitted directly by service technicians familiar with the machine.
FAQ
A: It is the pressure sensor / pressure transducer of an Ingersoll Rand air compressor. It measures the compressed-air pressure and sends a signal to the controller, which uses the reading to regulate loading, unloading and the working pressure.
A: Per public listings, 49154016 and 22359632 are cross-referenced as interchangeable IR pressure sensors, and 49154016 is referenced as the IR screw air compressor pressure sensor. Please confirm the number on your original sensor and your machine model before ordering.
A: This is the pressure sensor for Ingersoll Rand air compressors, referenced for the screw type (per listing). Please confirm the exact machine model and the sensor spec against your original part before ordering; if you are not sure, send us your machine details and we will help you confirm.
A: Per listings, these sensors are also grouped with 24571283, 23451859 and 23800584 in IR pressure-sensor cross-references. Please confirm the correct number for your machine before ordering.
A: The sensor converts the air pressure it senses into an electrical signal that the controller can read. The controller uses the reading to load the compressor when pressure is low and unload when the set pressure is reached, keeping the system within the working range.
A: Common signs include: unstable or incorrect system pressure, the compressor loading / unloading at the wrong times, pressure readings that are inaccurate, erratic or failed, and repeated pressure alarms or trips. Any of these can indicate the sensor needs replacing.
A: Compare the sensor reading against a known-good gauge / the actual system pressure. If the reading is inaccurate, erratic or missing, the sensor may be faulty. Check the wiring / connector first, then confirm the sensor against the original specification before replacing.
A: The controller gets an incorrect pressure reading, so it cannot regulate loading / unloading and the working pressure correctly. This can cause unstable system pressure, incorrect loading/unloading, lower efficiency, and repeated trips or alarms. Replacing the sensor restores correct control.
A: These are replacement sensors manufactured to match the Ingersoll Rand OEM specification; if you require original Ingersoll Rand parts, please let us know. Replacing the sensor is normally a straightforward swap carried out by service technicians: isolate and depressurize the line, disconnect the wiring, replace the sensor, reconnect and verify the reading after restart. If you need service guidance, please contact us.
Get a Quote for Your Compressor Part
Looking for the right replacement part? Send us your part number, compressor model, or dimensions, and our team will help you confirm the correct product.